Stroomtangen die u om een kabel heen kunt klampen zonder
de kabel te hoeven beschadigen en zonder dat u de werkende
installatie moet onderbreken. Stroomtangen zijn ontworpen
met bekken die open kunnen, om zo om een kabel heen te doen
en als ze dicht zijn kunnen ze het magnetische veld meten en
zo de stroomopname.
Stroomtangen bieden een veilige,
kosten efficiente, simpele en precieze manier van stroom
metingen
Onze stroomtangen werken samen met onze Pico
Oscilloscopen, Pico data Logger en alle andere bekende
merken van oscilloscopen en multimeters.
 ta167: 200A / 2000A DC Current Probe
High performance current probe . The 2000A range is ideal for use with modern diesel and high capacity petrol engines where starter currents can exceed 600A
pp218: 60 A AC/DC Current Clamp (4mm)
This current clamp will measure both AC and DC currents in the range 10 mA to 60 A. Features include a selectable calibrated voltage output. Supplied with 4 mm (banana) plug type connectors.
pp264: 60 A AC/DC Current Clamp (BNC)
This improved version features superior shielding against interference and is terminated in a BNC connector allowing it to be connected directly to your PicoScope.
pp218/pp264Current Clamp Specifications |
Range |
10 mA
to 60 A AC/DC |
AC Frequency tange |
Up to
20kHz |
Maximum conductor size |
9mm |
Ouput connectors |
4mm bana plus (pp218), BNC-Male (pp264 |
Operating enviromant |
0 °C to 50
°C, 70%RH |
ta138: 200 A AC Current Clamp (4 mm)
 Not being powered by batteries this unpowered current clamp is ideally suited to applications where current consumption is being monitored over long periods of time. Supplied with 4 mm (banana) plug type connectors.
ta138 Current Clamp Specifications |
Range (1mV/A) |
0.1A to 200A AC RMS |
Accuracy |
±
2%,
±
0.5 A |
Maximum Output impedance |
1kΩ |
Maximum Conductor size |
16mm |
Operating environment |
0 °C to 50
°C |
Storange Environment |
-30 °C to 60
°C |
Dimensions (W x L x D) |
111 x 50 x 33 mm |
Weight |
129 g |
Standards |
IEC1010-1 (1995) EN61010-1 (2001) Category II
600V Category III 300V |
ta011: 400 A AC Current Clamp (4 mm)
Not being powered by batteries this unpowered current clamp is ideally suited to applications where current consumption is being monitored over long periods of time. Supplied with 4 mm (banana) plug type connectors.
ta011 Current Clamp Specifications |
Range 1mV/A 10mV/A |
0.1A to 400A AC RMS
0A to 200A AC RMS |
Accuracy |
±
2%,
±
0.5 A |
Output voltage 1mV/A 10mV/A |
1 mV AC per 1A AC
1 mV AC per 0.1A AC |
Maximum Output impedance |
45Ω |
Maximum Conductor size |
28mm |
Operating environment |
0 °C to 50
°C |
Storange Environment |
-20 °C to 60
°C |
Dimensions (W x L x D) |
64 x 143 x 30 mm |
Weight |
185 g |
Standards |
IEC1010-1 (1995) EN61010-1 (2001) Category II
600V Category III 300V |
pp179: 600 A AC/DC Current Clamp (4 mm)
This current clamp can measure currents up to 600 amps for both AC (up to 400 Hz) and DC currents. Features includes a low–battery indicator. Supplied with 4 mm (banana) plug type connectors.
pp266: 600 A AC/DC Current Clamp (4 mm)
This current clamp can measure currents up to 600 amps for both AC (up to 400 Hz) and DC currents. Features includes a low–battery indicator. Supplied with 4 mm (banana) plug type connectors.
pp179/pp266
Current Clamp Specifications |
Accuracy |
DC |
0 to
600 A ±
(2% reading +2 A) |
AC |
0 to 300 A ±
(2% reading +2 A) |
AC/DC |
300
to 500 A ±
(3% reading +2 A) |
AC/DC |
500
to 600 A ±
(6% reading +2 A) |
AC frequency
range |
50 Hz
to 400 Hz |
Voltage Output |
1mV
per 1 A (0 to 600mV AC & DC) |
Maximum
Conductor size |
30mm |
Output
connectors |
4mm
banana plugs (pp179), BNC-Male (pp266) |
Operating
Enviroment |
0 °C to 50
°C , 70% RH |
|